Description
Base Specifications | |
---|---|
FPA | Low SWaP Cooled MWIR 640×512 with cold filter |
Pixel Pitch | 15 μm |
NETD | <15mK @ +50ºC |
Spectral region | 3.2 to 3.4 μm |
Lenses | 18ºx13º (Other lenses available under demand) |
Raw video data | 15 bits |
Data Protocol | USB (optional: GigE) |
Camera Control | Serial (optional: Ethernet) |
MDLR (for CH4)* | 0,35 g/h |
Power | Cooler: <12 W (Cooldown) / <5 W (nominal) / Electronics: 1W |
Voltage | Cooler 8-16 VDC / Electronics: 5 VDC (USB) |
Material | 6068 aluminum |
Max. dimensions | 75 x 80 x 250 mm |
Weight (35 mm lens) | 890 g |
Mechanical interface | 1/4 ” UNC |
Operating Temp. Range | -10ºC to +50ºC |
Storage Temp. Range | -40ºC to +71ºC |
Maximum relative humidity | 0.95 |
Certifications | |
---|---|
EMC (EN 61326:2013) | |
IP65 (EN 60529:2018) | |
EPA OOOOa COMPLIANCE |
Gases Detected | |
---|---|
Methane | CH4 |
Acetic Acid | C2H4O2 |
Turpentine | C10H16 |
Benzene | C6H6 |
1,3-Butadiene | C4H6 |
Butane | C4H10 |
Ethane | C2H6 |
Ethanol | C2H6O |
Ethyl Hexyl Acrylate | C11H20O2 |
Ethylene | C2H4 |
Ethylene Glycol | C2H6O2 |
Ethylbenzene | C8H10 |
Ethylene oxide | C2H4O2 |
Methanal | CH2O |
Heptane | C7H16 |
Hexane | C6H14 |
Methanol | CH4O |
MEK | C4H8 |
Octane | C8H18 |
Pentane | C5H12 |
Phenol | C6H6O |
Propane | C3H8 |
Propylene | C3H6 |
Toluene | C7H8 |
Innovative capabilities assembled under a single control software
High-sensitivity Mode
SENSIA’s Optical Gas Imaging (OGI) cameras can detect fugitive emissions of industrial gases using the high-sensitivity gas detection functionality. This feature, based on advanced image processing techniques, allows to show these invisible gases as clouds of smoke highlighted against the background scenario.
RedLook analytics is delivered for post-processing of the radiometric or compressed video acquired during the measurement campaign.
On board computer
RedLook is the software application that runs in the control computer. It is an application developed for Smart Optical Gas Imaging processing and data management for SENSIA instruments oriented to LDAR campaigns. RedLook provides advanced functionalities devoted to enhancing the detection of fugitive emissions such as different gas processing algorithms and automatic image contrast control, among a wide range of features.
This computer will oversee the image processing computing workload of the raw data provided by the OGI and will provide the thermal image streaming via RTSP protocol to the control computer. Additionally, it is devoted to power the detector and electronics of the OGI and to provide the back-up storage. This computer will include a software for video acquisition/processing and OGI management that will run the gas detection algorithms for an increased gas sensing performance. This software will also perform recordings of the OGI camera according to ground computer commands.
RedLook will show the video streaming with the running algorithms and the metadata of the OGI and will communicate it with third-party systems using RTSP or ONVIF protoco